http://global.pro-face.com/sites/all/themes/Proface/images/box.png); background-position: 0% 50%; background-repeat: no-repeat;">Functional Specifications

Type TFT Color LCD
Resolution (pixels) 320 x 240 (QVGA)
Active display area (W x H) 115.2 x 86.4 mm (4.53 x 3.40 in.)
Display Colors 65,536 colors
Backlight White LED
Non-exchangeable
LED ON / OFF control, adjustable screen saver activation time
Brightness adjustment 16 levels of adjustment available via touch panel in the configuration menu
Language Fonts *1 Japanese, ASCII, Chinese (Simplified), Chinese (Traditional), Korean, Cyrillic, Thai
Character sizes 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts
Font sizes Width can be expanded 1 to 8 times. Height can be expanded 1/2 and 1 to 8 times.
8 x 8 pixels 40 characters per row x 30 rows
8 x 16 pixels 40 characters per row x 15 rows
16 x 16 pixels 20 characters per row x 15 rows
32 x 32 pixels 10 characters per row x 7 rows
MemoryApplication memory *2 FLASH EPROM 16 MB
(includes screen editing program and extended logic program)
Logic program area FLASH EPROM 132 KB *3 (equivalent to 15,000 steps)
Font area FLASH EPROM 8 MB (when limit exceeded, uses application memory)
Data backup nvSRAM 128 KB (rechargeable lithium battery for data backup)
Variable area nvSRAM 64 KB (rechargeable lithium battery for data backup)
Touch PanelType Resistive Film (analog)
Lifetime 1 million touches or more
InterfaceSerial (COM1) RS-232C/RS485 x 1 

RS-232C (Connector type: RJ45, Isolation: None, Maximum baud rate: 115,200 bps, Cable Type: Shielded, Cable Maximum length: 15 m (49 ft), 5 Vdc power supply for RS-232C: None)

RS-485 (Connector type: RJ45, Isolation: None, Maximum baud rate: 115,200 bps, Cable Type: Shielded, Cable Maximum length: 200 m (656 ft), Polarization: Setting is required via software when connecting Multiple LTs. Refer to the "GP-Pro EX Device/ PLC Manual" for the setting. 5 Vdc power supply for RS-485: None) *4

CANopen (Master) CAN-CiA (ISO 11898-2:2002 Part 2), Connector: D-sub9 (pin)
Ethernet IEEE802.3 compliant Ethernet x 1

(Connector type: RJ45, Driver: 10 M half duplex (auto negotiation)/ 100 M full duplex (auto negotiation), Cable type: Shielded, Automatic cross-over detection: Yes)

USB (Type A) USB 2.0 (Type A) x 1
(Power Supply Voltage: 5Vdc +/-5%, Maximum Current Supplied: 500mA, Maximum Transmission Distance: 5m (16.4 ft.))
USB (Mini-B) USB 2.0 (Mini-B) x 1
ControlDIO(Sink Type) 20 Points Standard Input (including 2 Points for Fast Input)
10 Points Standard Output, 2 Points for Fast Output
  1. http://global.pro-face.com/images/common/listmark2.gif) 0px 0.3em no-repeat;">*1 Please refer to the http://www.pro-face.com/files/images/common/link_images/ico_blank.png); background-position: 100% 50%; background-repeat: no-repeat;">GP-Pro EX Reference Manual for details on font types and character codes.
  2. http://global.pro-face.com/images/common/listmark2.gif) 0px 0.3em no-repeat;">*2 Capacity available for user application.
  3. http://global.pro-face.com/images/common/listmark2.gif) 0px 0.3em no-repeat;">*Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
  4. http://global.pro-face.com/images/common/listmark2.gif) 0px 0.3em no-repeat;">*4 2-wire connection is available for RS-485. When a Device/PLC supports 2-wire connection, 4 wires (RXD+, TXD+, RXD-, and TXD-) can be short-circuited to be 2 wires (RXD+ and TXD+ = D1, RXD- and TXD- = D0). For details on the connection, refer to the connection manual.
http://www.pro-face.com/images/common/arrow05.gif) 99% 50% no-repeat;">Page Top

General Specifications

International Safety Standards
Rated Input Voltage 24 Vdc
Input Voltage Limits 20 to 28.8 Vd
Acceptable Voltage Drop 10 ms or less at 20.4 Vdc
Power Consumption 10 W or less
In-Rush Current 30 A or less at 28.8 Vdc
Voltage Endurance between power terminal and frame ground (FG) 500 Vdc for 1 minute
Insulation Resistance between power terminal and FG 10 MΩ or higher at 500 Vdc
http://www.pro-face.com/images/common/arrow05.gif) 99% 50% no-repeat;">Page Top

http://global.pro-face.com/sites/all/themes/Proface/images/box.png); background-position: 0% 50%; background-repeat: no-repeat;">Environmental Specifications

Standard compliance IEC 61131-2
Ambient operating temperature for the display and the rear moduleHorizontal installation 0 to 50°C (32 to 122°F)
Vertical installation 0 to 40°C (32 to 104°F)
Storage temperature - 20 to 60°C (- 4 to 140°F)
Storage altitude 0 to 10,000 m (0 to 32,808 ft)
Operating altitude 0 to 2,000 m (0 to 6,560 ft)
Surrounding Air and Strage Humidity 5 to 85% w/o condensation (non-condensing, wet bulb temperature 39°C (102.2°F) or less)
Degree of pollutionIEC60664 2
Degree of protectionIEC61131-2 IP20 with protective covers in place
Corrosive gases Free of corrosive gases
Dust ≤0.1 mg/m3 (10-7 oz/ft3) (non-conductive levels)
Atmospheric pressure (Operating Altitude) 800 to 1,114 hPa (2000 m (6,561 ft) or lower)
Vibration resistanceMounted on a DIN rail 3.5 mm (0.138 in.) fixed amplitude from 5 to 8.4 Hz
9.8 m/s2 (1 gn) fixed acceleration from 8.4 to 150 Hz
Mounted on a panel 3.5 mm (0.138 in.) fixed amplitude from 5 to 8.6 Hz
9.8 m/s2 (1 gn) fixed acceleration from 8.6 to 150 Hz
Mechanical shock resistanceMounted on a DIN rail 147 m/s2 (15 gn) for a duration of 11 ms
Mounted on a panel 147 m/s2 (15 gn) for a duration of 6 ms
Electrostatic dischargeIEC/EN 61000-4-2 8 kV (air discharge)
6 kV (contact discharge)
Rediated radio frequency electromagnetic fieldsIEC/EN 61000-4-3 10 V/m (80 MHz to 3 GHz)
Fast transients / Burst noiseIEC/EN 61000-4-4 Power lines: 2 kV
Digital I/O: 1 kV
Relay outputs: 2 kV
Ethernet line: 1 kV
COM line: 1 kV
CAN line: 1 kV
Surge immunityIEC/EN 61000-4-5 Power supply: CM: 1 kV; DM: 0.5 kV
Digital I/O: CM: 1 kV; DM: 0.5 kV
Shielded cable: 1 kV
CM = common drive
DM = differential drive
Conducted disturbances induced by radio-frequency fieldsIEC/EN 61000-4-6 10 Veff (0.15 to 80 MHz)
Mains terminal dusturbance voltageEN 55011 (IEC/CISPR11) 150 to 500 kHz, quasi peak 79 dBμV
500 kHz to 30 MHz, quasi peak 73 dBμV
Electric field strengthEN 55011 (IEC/CISPR11) 30 to 230 MHz, quasi peak 10 m @40 dBμV/m
230 MHz to 1 GHz, quasi peak 10 m @47 dBμV/m
Vibration immunity (operating) IEC 61131-2
Protection structure NEMA TYPE 4X (indoors, with panel embedded)
Protection (front module) IP65f - (IEC 60529)
Protection (rear module) IP 20 - (IEC 60529)
Shock immunity (operating) IEC 61131-2
15 gn 11 ms
Cooling method Natural air circulation
Weight 749 g (26.41 oz)
Color Front module: PT404 Rear module: RAL 7032
Material Front module: PAA+GF 
Rear module: PC/PBT
http://www.pro-face.com/images/common/arrow05.gif) 99% 50% no-repeat;">Page Top

http://global.pro-face.com/sites/all/themes/Proface/images/box.png); background-position: 0% 50%; background-repeat: no-repeat;">Digital Inputs

Digital Input Characteristics

Rated Current 5 mA
Inrush ValuesVoltage 30 Vdc
Current 6.29 mA max.
Input impedance 4.9 kΩ
Input type Sink/Source
Rated voltage 24 Vdc
Maximum Allowable Voltage 28.8 Vdc
Input limit valuesON Voltage 15 Vdc or more (15 to 28.8 Vdc)
OFF Voltage 5 Vdc or less (0 to 5 Vdc)
ON Current 2.5 mA or more
OFF Current 1.0 mA or less
IsolationMethod Photo coupler Isolation
Between internal logic 500 Vdc
Filtering 0.5 ms x N (N is 0 to 63)
IEC61131-2 edition 3 type Type 1
Compatibility Supports 2 wire and 3 wire sensors
Cable type and length Shielded: Maximum 100 m (328 ft)
Non-shielded: 50 m (164 ft)
Terminal blocks Type: 3.5 mm (0.137 in.) pitch
Terminal blocks are removable
Input paralleling No
3_dio_input.gif
 
* I0 and I1 are Fast input terminals and can be also used as a Standard input. For specifications, see the specifications of Fast Input.
http://www.pro-face.com/images/common/arrow05.gif) 99% 50% no-repeat;">Page Top

High Speed Counter Input Characteristics

<th style="border: 1px so
Rated CurrentVoltage 24 Vdc
Current 7.83 mA
Inrush valuesVoltage 30 Vdc
Current 9.99 mA
Input impedance 3.2 kΩ
Input type Sink/Source
Rated voltage 24 Vdc
Maximum Allowable Voltage 28.8 Vdc
Input limit valuesON Voltage 15 Vdc or more
OFF Voltage 5 Vdc or less
ON Current 5 mA or more
OFF Current 1.5 mA or less

Isolation

Method Photo coupler Isolation
Between channels logic 500 Vdc
Filtering None, 4 μs, 40 μs
IEC61131-2 edition 3 type Type 1
Compatibility Supports 2 wire and 3 wire sensors
CableType Shielded
Length Maximum 10 m (33 ft)
Terminal blocks Type: 3.5 mm (0.137 in.) pitch
Terminal blocks are removable
Maximum frequency · 100 kHz is the maximum frequency for Single-phase
· 50 kHz is the maximum frequency for 2-phase 
· Duty Rate: 45 to 55%
Phase Counting Mode · Single phase
· 2 Phase x2
· 2 Phase x4
· 2 Phase x2 Reverse
· 2 Phase x4 Reverse
Response timeMarker 1 ms

Sản phẩm cùng loại

r5b

mhcamung

Lượt truy cập

5571131
Hôm nay
Hôm qua
Tuần này
5574
4515
10089
Thông số chức năng Loại màn hình TFT LCD màu Kích thước màn hình 10.4 " Độ phân giải 640 X 480 pixel...
Ngày nay có rất nhiều dòng cảm biến ra đời từ nhiều hãng như Omron, Sick, Julong, Riko... với nhiều tính năng cũng như...
Là thiết bị làm thay đổi tần số dòng điện trong cuộn dây bên trong động cơ spindle, qua đó điều khiển tốc độ...
Biến tần 1 pha là loại biến tần ngõ vào 1 pha 220V, ngõ ra là 3 pha 220V. Biến tần 1 pha này dùng cho loại động cơ 3 pha...

CÔNG TY TNHH KỸ THUẬT ĐIỆN HIỆP LỰC

Trụ sở: 97/4 KP.2, P. Thới An, Q.12, TPHCM

    VPGD: 32/1 Lê Văn Huân, P13, Q.Tân Bình, TPHCM

028.6297.4701 / 702 / 703

thaibinhdhl@gmail.com

Thống kê truy cập

Hôm nay
Hôm qua
7 ngày qua
Lượt truy cập:
5574
4515
10089
5571131