Supply Voltage and Current 10 to 30V dc (10% max. ripple) Opposed Emitters:25 mA (exclusive of load)
Opposed Receivers:20 mA (exclusive of load)
Range Opposed:15 m
Supply Protection Circuitry Protected against reverse polarity and transient voltages
Output Configuration Solid-state complementary (SPDT) dc switch: NPN (current sinking) or PNP (current sourcing), depending on model. The dark operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.
Output Rating 100 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 100 mA OFF-state leakage current::less than 1 µA @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA dc; less than 1.5V @ 150 mA dc
Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short circuit of outputs
Output Response Time 3 milliseconds ON; 1.5 milliseconds OFF; response time is independent of signal strength.
Delay at Power-up 100 milliseconds; outputs do not conduct during this time.
Repeatability 375 microseconds; repeatability is independent of signal strength.
Indicators 2 LED Indicators:Green and Yellow
Green ON steady:power to sensor is ON
Green flashing:output is overloaded
Yellow ON steady:light-operate (LO) output is energized
Yellow flashing:marginal excess gain (1-1.5x) in light condition, LO output is energized
Construction Thermoplastic polyester housing with polycarbonate or acrylic lenses. Two jam nuts are included with each sensor.
Environmental Rating Leakproof design rated NEMA 6P (IEC IP67)
Connections 2 m or 9 m attached cable, or 4-pin Pico-style quick-disconnect fitting. QD cables are ordered separately.
Operating Conditions Temperature:-40° to +70° C
Relative humidity:90% @ 50° C (non-condensing)
Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)

 


Sản phẩm cùng loại

r5b

mhcamung

Lượt truy cập

5070329
Hôm nay
Hôm qua
Tuần này
4888
7677
44008
Ngày nay có rất nhiều dòng cảm biến ra đời từ nhiều hãng như Omron, Sick, Julong, Riko... với nhiều tính năng cũng như...
Là thiết bị làm thay đổi tần số dòng điện trong cuộn dây bên trong động cơ spindle, qua đó điều khiển tốc độ...
Biến tần 1 pha là loại biến tần ngõ vào 1 pha 220V, ngõ ra là 3 pha 220V. Biến tần 1 pha này dùng cho loại động cơ 3 pha...
Nguồn tổ ong 5V 12V 24V Ngày nay khi nhu cầu sử dụng các thiết bị điện tự động hóa ngày càng nhiều, thì các thiết...

CÔNG TY TNHH KỸ THUẬT ĐIỆN HIỆP LỰC

Trụ sở: 97/4 KP.2, P. Thới An, Q.12, TPHCM

    VPGD: 32/1 Lê Văn Huân, P13, Q.Tân Bình, TPHCM

028.6297.4701 / 702 / 703

thaibinhdhl@gmail.com

Thống kê truy cập

Hôm nay
Hôm qua
7 ngày qua
Lượt truy cập:
4888
7677
44008
5070329